26
27
Test run
3
With Console A
Direction
selector
switch
RUN/STOP
switch
Console A
connection
cable (option)
Speed potentiometer Power LED
RUN
switch
Rotate
direction
selector
switch
I
1 input
enabled
switch
Console A
(option)
Set the RUN switch on the front panel to “RUN”, the rotate direction selector switch to
“CCW”, and the I1 input enable switch (SW3) on the back of the product to “ON". Change
parameter 31 from “Vol - F” to “Vol - A” using Digital key pad or PANATERM for BL.
To start the motor, set RUN/STOP switch to RUN position, and to stop the motor, set the
switch back to STOP position.
Rotating direction can be switched from the direction selector switch on the side of
Console A.
If the rotation direction is reversed while the motor in the RUN mode, the rapid directional
switching can cause tripping due to the inertia of load.
Rotation speed can be adjusted by the speed potentiometer.
Turn off power when the motor is to be stopped for a long time.
■
Attention
When power is turned off with RUN/STOP switch in RUN position, and turned
on again, the motor will start again, which is dangerous. When turning on pow-
er, always make sure that the switch is in STOP position.
• When gear head is incorporated, the rotation direction of motor and that of gear
output shaft are reversed for some gear reduction ratio. Please refer to the table of the
permissible torque (P.28).
• For connection to Consol A, use optional Consol A connecting cable. (option: P.74)
• The procedure descried above is for operation according to factory default. Different
procedure is required if internal parameters have been changed by using the Digital
key pad or PANATERM for BL.
<Connections on Consol A and I/O connector>
I/O connector side
Terminal No.
Terminal
symbol
Lead color of
a cable
Console A side
terminal No.
1
I
1
Brown
1
2
I
2
Red
2
3
I
3
—
4
I
4
—
5
I
5
—
6
COM
Orange
3
7
FIN
Yellow
4
8
+5V
Green
5
9
01
—
10
02
—
4
Digital key pad
Please refer toTest run (Digital key pad) (P.41).
Digital key pad