62
63
Outline of PANATERM for BL/
Example of an operation pattern
Outline of PANATERM for BL
Communicating software “PANATERM for BL” can do the following thing.
(1) Setting and saving of parameters of brushless amplifier and writing setting to memory
EEPROM.
(2) Monitor of input/output signals, monitor of a load factor.
(3) The present trip display and reference of a trip history.
(4) Data measurement of waveform graphics, and the call of preservation data.
Example of an operation pattern
When using the
I
1 input, turn on the
I
1 input enable switch (SW3) on the back of the
product and set the RUN switch on the front of the product to RUN.
When using the
I
2 input, set the CCW / CW switch on the front of the product to CCW.
• Example of running pattern by use of 2nd acceleration / deceleration time.
When you choose “ 32 Operation mode selection” at
: 1st speed operation
mode, choose “ 33
I
1/
I
2 function selection” at
: (RUNSTOP, FORWARD-
REVERSE), and choose
“ 34
I
3 function selection” at
: 2nd acceleration and
deceleration time.
Run/Stop switch (
I
1)
1st acceleration time
1st deceleration time 2nd acceleration time
2nd deceleration time
Zero-speed
control
Zero-speed
control
CCW/CW switch (
I
2)
2nd acceleration/
deceleration time (
I
3)
Internal speed
(0-th speed)
Internal speed
(0-th speed)
CCW
CW
• Example of operation pattern in 2nd speed operation mode
When you choose “ 32 Operation mode selection” at
: 2nd speed operation
mode, “
I
3” is choosing of speed setting, and works as follows:
I
3
Speed setup
OFF
Internal speed (0-th speed ) or FIN
ON
1st speed
Run/Stop switch (
I
1)
1st acceleration time
1st deceleration time
Zero-speed control
CCW/CW switch (
I
2)
1st speed (
I
3)
Internal speed
(0-th speed)
1st speed
CCW
CW
Parameter
No.
Name of parameter
Description
51 Retrial selection
Automatic reset in trip (trip retrial) can be set here. Trip can be is
automatically reset to allow operation to continue. Use this func-
tion only on such equipment that has no problem of safety even if
the motor is automatically restarted.
•
Retrial is impossible if trip is by Overcurrent error
,
Sensor error
,
System error
,
User param-
eter error
,
or System parameter error
.
When
(NO) is selection, retrial is not effective.
When
to
is selection, retrial is made for the
set number of times. When 2 hours has elapsed with no trip, the
number of retrying times is initialized to 0.
Set the interval between retrials by “ 52 Retrial start time”. When
trip occurs in excess of preset number of trials, the brushless
amplifier outputs trip signal and stops.
•
During retrial, trip signal is not output (It is stored in trip history)
52 Retrial start time
You can set waiting time until retrial operation is performed after
tripping is found. You can set 1 to 120 seconds.
54 Parameter
initializing
Parameters can be initialized to the factory default.
<Initializing procedure>
Cut off power with
(YES) selection, and turn on power
again after display has disappeared, then
is displayed,
and parameters are initialized to the factory default.
57 Parameter copy
Parameters can be copied.
(NO) Parameters are not copied
(PARAMETER-INITIALIZE):
Initialization of Digital key pad data
(PARAMETER-LOAD):
Reading parameters into Digital key pad data
(PARAMETER-PROGRAM):
Writing parameters to the brushless amplifier
See the copying method of parameters on P.44 for detail
F0 For manufacturer use It cannot be changed.
The function of parameters