53
■
Lot condition: LTC
Sets the condition of “Lot Function” to change characters depending on date/time and counter values.
Setting / Readout data of lot condition
STX
LTC
Sub
command
[Lot No.] [Lot target] [Period unit]
4-byte
(Check sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
Readout request of lot condition
STX
LTC
R
[Lot No.]
1-byte
(Check sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
Lot No.
1
“0”–“7”
“4”–“7”: common lot
Lot target
2
“00”: Current
“01”–“08”: expiry 1 to 8
“10”–“17”: counter 0 to 7
The unit of period to switch the character string
for marking is indicated.
Period unit
1
“0”: Year or counter
“1”: Month
“2”: Day
“3”: Y/M
“4”: M/D
“5”: Day of week
“6”: Hour
“7”: Week
“8”: Minute
“9”: Hour/Min.
“A”: Week-based year
Reference
•
When the period unit of the lot condition (LTC command) is changed, the lot period and lot character (LTS command)
settings registered to that lot number are deleted.
ME-LPMSZ-SR-9
Summary of Contents for LP-M Series
Page 8: ...1 Before External Control ME LPMSZ SR 9...
Page 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Page 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Page 165: ...Troubleshooting ME LPMSZ SR 9...
Page 186: ...Character Code Table ME LPMSZ SR 9...
Page 199: ...Index ME LPMSZ SR 9...
Page 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Page 203: ...No 9000 0063 59V...
Page 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...