97
■
Laser power: LPW
Sets the laser power.
Setting / Readout data of laser power
STX
LPW
Sub
command
[Laser power]
5-byte
(Check sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
Readout request of laser power
STX
LPW
R
(Check sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
Laser power
5
Model type*
Setting range
LP-Sxxx/LP-Mxxx
“012.0”–“100.0”
LP-SxxxW
“020.0”–“100.0”
LP-Zxxx
“000.5”–“100.0”
(Set by increment of 0.5)
* For the detail of the model type, refer to “Target laser marker” (P.4).
■
Scan speed: SSP
Sets the scan speed of the laser.
Setting / Readout data of scan speed
STX
SSP
Sub
command
[Scan speed]
5-byte
(Check sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
Readout request of scan speed
STX
SSP
R
(Check sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
Scan speed
5
Model type*
Setting range [mm/s]
LP-Sxx0/LP-Sxx5
LP-Mxx0/LP-Mxx5/
LP-Zxx0
“00001”–“12000”
LP-Sxx2
“00001”–“06000”
LP-SxxW
“00001”–“03000”
LP-Mxx6/LP-Zxx6
“00001”–“08000”
* For the detail of the model type, refer to “Target laser marker” (P.4).
ME-LPMSZ-SR-9
Summary of Contents for LP-M Series
Page 8: ...1 Before External Control ME LPMSZ SR 9...
Page 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Page 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Page 165: ...Troubleshooting ME LPMSZ SR 9...
Page 186: ...Character Code Table ME LPMSZ SR 9...
Page 199: ...Index ME LPMSZ SR 9...
Page 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Page 203: ...No 9000 0063 59V...
Page 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...