150
Name
Data length
[byte]
Description
Remarks
X position
7
Model type*
Setting range [mm]
LP-Sxx0(W)
“-045.00”–“+045.00”
LP-Sxx5(W)
“-080.00”–“+080.00”
LP-Sxx2
“-027.50”–“+027.50”
LP-Mxx0/LP-Zxx0 “-060.00”–“+060.00”
LP-Mxx5
“-110.00”–“+110.00”
LP-Mxx6/LP-Zxx6 “-165.00”–“+165.00”
X, Y coordinate where the first character
is marked is indicated.
Y position
7
Character
interval
6
Model type*
Setting range [mm]
LP-Sxx0(W)
“000.00”–“090.00”
LP-Sxx5(W)
“000.00”–“160.00”
LP-Sxx2
“000.00”–“055.00”
LP-Mxx0/LP-Zxx0
“000.00”–“120.00”
LP-Mxx5
“000.00”–“220.00”
LP-Mxx6/LP-Zxx6
“000.00”–“330.00”
Indicates the gap between adjacent
characters.
Line interval
6
The line pitch to mark the next line is
indicated when the character string is
marked over two or more lines.
Font No.
1
“1”: Font 1
“2”: Font 2
The number corresponding to the 2 fonts
previously registered is indicated.
Bold line width
5
•
LP-F10 Mode
“-00.00”–“01.92” [mm]
•
LP-F10W Mode
Model type*
Setting range [mm]
LP-Sxx0(W)/LP-Sxx2/
LP-Mxx0/LP-Zxx0
“00.00
”
–“02.00
”
LP-Sxx5(W)/LP-Mxx5/
LP-Mxx6/LP-Zxx6
“00.00
”
–“03.20
”
Laser power
correction
3
“000”–“200” [%]
•
The correction ratio is calculated using
the value set at the laser condition as
100%.
•
Laser Pulse Cycle Correction can be
specified only in LP-F10 mode.
Scan speed
correction
3
“050”–“200” [%]
Laser pulse
cycle correction
(3)
“050”–“200” [%]
(LP-F10 mode only)
* For the detail of the model type, refer to “Target laser marker” (P.4).
2. When markings from is slope/slope proportional
Data length: 66-byte (LP-F10 mode), 63-byte (LP-F10W mode)
Name
Data length
[byte]
Description
Remarks
Character
condition No.
2
“01”–“30”
Start line
2
“01”–“30” [row]
The start and end line of character
string for marking with this condition is
indicated.
End line
2
“01”–“30” [row]
Marking shape
1
“1”: Slope
“5”: Slope proportional
When the tilt angle is set to 0 degree,
this item is readout as “0” (straight line)
or “4” (straight line proportional).
ME-LPMSZ-SR-9
Summary of Contents for LP-M Series
Page 8: ...1 Before External Control ME LPMSZ SR 9...
Page 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Page 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Page 165: ...Troubleshooting ME LPMSZ SR 9...
Page 186: ...Character Code Table ME LPMSZ SR 9...
Page 199: ...Index ME LPMSZ SR 9...
Page 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Page 203: ...No 9000 0063 59V...
Page 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...