Lot character string: LTS
Sets the character string used for “Lot function” to change characters depending on date/time.
Setting / Readout data of lot character string
Set the lot character string for the specified number with the following format:
STX
LTS
Sub
command
[Lot No.] [Period unit No.] [Start period]
[End period] [Marking character string]
Max. 33-byte
(Check sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
Readout request of lot character string
STX
LTS
R
[Lot No.] [Period unit No.]
3-byte
(Check sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
Lot No.
1
“0”–“3”
Period unit
2
Period condition
Setting range
Year
“01”–“54”
Month
“01”–“12”
Day
“01”–“31”
Y/M
“01”–“54”
M/D
“01”–“54”
Hour
“01”–“24”
Week
“01”–“54”
Day of Week
“01”–“07”
The setting range varies depending on
the condition of period unit.
Start period
6
Period condition
Setting range
Year
“198000”–“209900”
Month
“000001”–“000012”
Day
“000001”–“000031”
Y/M
“198001”–“209912”
M/D
“000101”–“001231”
(The higher 4 characters:
month, the lower 2
characters: date)
Hour
“000000”–“000023”
Week
“000000”–“000054”
Day of Week
“000000”–“000006”
(“000000”: Sunday,
“000006”: Saturday)
The start/end period of marking character
string for setting is set.
The setting range varies depending on
the condition of period unit.
Set “999999” for both of start and end
period to delete it.
“999999” is indicated if the period which
has not been set is read out.
End period
6
Marking
character
string
Max. 18
Use the shift-JIS code.
(Up to 9 characters)
The character string to be marked with
the specified period is set. Specify 0-byte
of data length to delete the character
string of period.
Reference
•
The common lot (Lot function Nos. 4 to 7) cannot be set and read out. (NAK09 is returned.)
When the period unit exceeds the setting range above, NAK09 is returned.
ME-LPMSZ-SR-9
Summary of Contents for LP-M Series
Page 8: ...1 Before External Control ME LPMSZ SR 9...
Page 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Page 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Page 165: ...Troubleshooting ME LPMSZ SR 9...
Page 186: ...Character Code Table ME LPMSZ SR 9...
Page 199: ...Index ME LPMSZ SR 9...
Page 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Page 203: ...No 9000 0063 59V...
Page 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...