129
■ Marking character string (Shift-JIS code specified) : STR
Sets the marking character string by shift-JIS code. (For characters including KANA, KANJI and function characters)
Setting / Readout data of marking character string
Set the marking character string in the specified line number with the following format:
STX
STR
Sub
command
[Line No.] [Marking character string]
Max. 62-byte
(Check sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
Readout request of marking character string
STX
STR
R
[Line No.]
2-byte
(Check sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
Line No.
2
“01”–“30” [row]
Marking
character string
Max. 60
The character string to be set in the specified
line is specified with shift-JIS code. (Up to 30
characters) (However, the function character
should be specified by ASCII code.) Specify
0-byte to the character string to be deleted.
See the next page.
Reference
•
The line 31 and after cannot be set and read out. (NAK09 is returned.)
ME-LPMSZ-SR-9
Summary of Contents for LP-M Series
Page 8: ...1 Before External Control ME LPMSZ SR 9...
Page 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Page 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Page 165: ...Troubleshooting ME LPMSZ SR 9...
Page 186: ...Character Code Table ME LPMSZ SR 9...
Page 199: ...Index ME LPMSZ SR 9...
Page 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Page 203: ...No 9000 0063 59V...
Page 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...