Resync Interval
Description
Specifies the interval, in minutes, between periodic checks for updates
of the configuration files.
Value Range
1–40320
Default Value
10080
Configuration File Reference
CFG_CYCLIC_INTVL (Page 164)
Header Value for Resync Event
Description
Specifies the value of the "Event" header sent from the SIP server to
the unit so that the unit can access the configuration files on the
provisioning server.
Value Range
Max. 15 characters
Note
•
You cannot leave this field empty.
•
When the value for this setting is "check-sync" or "resync", the
unit will access the configuration files on the provisioning server
when the SIP server sends an event to notify the unit.
Default Value
check-sync
Configuration File Reference
CFG_RESYNC_FROM_SIP (Page 165)
4.7.4 Management Server
This screen allows you to configure the management server.
4.7.4.1 Management Server
Management Server URL
Description
Specifies the URL of the Auto-Configuration Server for using TR-069.
Document Version 2011-06
Administrator Guide
133
4.7.4 Management Server