Download Timing
Explanation
At a specified time each day
After the unit is powered on, it will check for and download configuration
files once per day at the specified time.
SIP Phone
Provisioning
Server
02:00
02:00
Power On
at 12:00
Check
Download
Check
Download
Check
Download
CFG_RESYNC_TIME="02:00"
The configuration files are downloaded at a set time each day:
•
Set a time by specifying "
CFG_RESYNC_TIME
".
Note
•
If the value for "
CFG_RESYNC_TIME
" is any valid value other
than an empty string, the unit downloads the configuration files
at the fixed time, and the settings specified in "
CFG_CYCLIC
",
"
CFG_CYCLIC_INTVL
", and "
CFG_RTRY_INTVL
" are
disabled.
•
The time is specified using a 24-hour clock ("00:00" to "23:59").
When directed
When a setting needs to be changed immediately, units can be directed to
download the configuration files by sending them a NOTIFY message that
includes a special event from the SIP server.
•
In the configuration file:
–
Specify the special event text in "
CFG_RESYNC_FROM_SIP
".
•
In the Web user interface:
–
Click the
[Maintenance]
tab, click
[Provisioning Maintenance]
,
and then enter the special event text in
[Header Value for Resync
Event]
.
Generally, "check-sync" or "resync" is set as the special event text.
40
Administrator Guide
Document Version 2011-06
2.2.4 Downloading Configuration Files
Summary of Contents for KX-UT133-B
Page 54: ...54 Administrator Guide Document Version 2011 06 3 1 4 Reset Web ID Password...
Page 136: ...136 Administrator Guide Document Version 2011 06 4 7 6 Restart...
Page 234: ...234 Administrator Guide Document Version 2011 06 5 7 2 SIP Settings...
Page 252: ...252 Administrator Guide Document Version 2011 06 7 4 Local Firmware Update...
Page 257: ...Index Document Version 2011 06 Administrator Guide 257...