Configuration File Reference
DIAL_TONE1_FRQ (Page 185)
Tone Timings
Description
Specifies the pattern, in milliseconds, of dial tones using up to 10 whole
numbers (off 1, on 1, off 2, on 2…) separated by commas.
Value Range
0–16000 (0: Infinite time)
Note
•
The unit will not play the tone for the duration of the first value,
play it for the duration of the second value, stop it for the
duration of the third value, play it again for the duration of the
fourth value, and so on. The whole sequence will then repeat.
For example, if the value for this setting is "100,100,100.0", the
unit will not play the tone for 100 ms, play it for 100 ms, stop it
for 100 ms, and then play it continuously.
•
It is recommended that you set a value of 60 milliseconds or
more for the first value (off 1).
Default Value
60,0
Configuration File Reference
DIAL_TONE1_TIMING (Page 185)
4.6.4.2 Busy Tone
Tone Frequencies
Description
Specifies the dual-tone frequencies, in hertz, of busy tones using 2
whole numbers separated by a comma.
Value Range
0, 200–2000 (0: No tone)
Default Value
480,620
Configuration File Reference
BUSY_TONE_FRQ (Page 188)
Tone Timings
Description
Specifies the pattern, in milliseconds, of busy tones using up to 10
whole numbers (off 1, on 1, off 2, on 2…) separated by commas.
Note
•
It is recommended that you set a value of 60 milliseconds or
more for the first value (off 1).
Value Range
0–16000 (0: Infinite time)
Default Value
60,500,440
Configuration File Reference
BUSY_TONE_TIMING (Page 188)
Document Version 2011-06
Administrator Guide
123
4.6.4 Tone Settings
Summary of Contents for KX-UT133-B
Page 54: ...54 Administrator Guide Document Version 2011 06 3 1 4 Reset Web ID Password...
Page 136: ...136 Administrator Guide Document Version 2011 06 4 7 6 Restart...
Page 234: ...234 Administrator Guide Document Version 2011 06 5 7 2 SIP Settings...
Page 252: ...252 Administrator Guide Document Version 2011 06 7 4 Local Firmware Update...
Page 257: ...Index Document Version 2011 06 Administrator Guide 257...