Setting Order
Priority
Setting Method
4
1
Settings configured from the Web user interface or the phone user
interface
According to the table, settings configured later override previous settings (i.e., settings listed lower in the table
have a higher priority).
If different values are specified for the same setting by the master configuration file and Web user interface
programming, the value specified from the Web user interface is applied. This is because values specified from
the Web user interface have a higher priority.
For settings configured from the Web user interface and the phone user interface, the value specified most
recently receives priority.
2.4 Configuration File Specifications
The specifications of the configuration files are as follows:
File Format
The configuration file is in plain text format.
File Size
The maximum size of a configuration file is 120 KB. Regardless of the number of configuration files, the total
size of the configuration files must be 120 KB or less.
Lines in Configuration Files
A configuration file consists of a sequence of lines, with the following conditions:
•
Each line must end with "<CR><LF>".
•
The maximum length of a line is 537 bytes including "<CR><LF>".
•
The following lines are ignored:
–
Lines that exceed the limit of 537 bytes
–
Empty lines
–
Comment lines that start with "
#
"
•
Configuration files must start with a comment line containing the following designated character sequence
(44 bytes):
# Panasonic SIP Phone Standard Format File #
The hexadecimal notation of this sequence is:
23 20 50 61 6E 61 73 6F 6E 69 63 20 53 49 50 20
50 68 6F 6E 65 20 53 74 61 6E 64 61 72 64 20 46
6F 72 6D 61 74 20 46 69 6C 65 20 23
•
To prevent the designated character sequence being altered by chance, it is recommended that the
configuration file starts with the comment line shown below:
# Panasonic SIP Phone Standard Format File # DO NOT CHANGE THIS LINE!
•
Configuration files must end with an empty line.
•
Each parameter line is written in the form of XXX="yyy" (XXX: parameter name, yyy: parameter value).
The value must be enclosed by double quotation marks.
•
A parameter line written over multiple lines is not allowed. It will cause an error on the configuration file,
resulting in invalid provisioning.
Configuration Parameters
•
The unit supports multiple telephone lines. For some parameters, the value for each line must be specified
independently. A parameter name with the suffix "
_1
" is the parameter for line 1; "
_2
" for line 2, and so on.
Document Version 2011-06
Administrator Guide
47
2.4 Configuration File Specifications
Summary of Contents for KX-UT133-B
Page 54: ...54 Administrator Guide Document Version 2011 06 3 1 4 Reset Web ID Password...
Page 136: ...136 Administrator Guide Document Version 2011 06 4 7 6 Restart...
Page 234: ...234 Administrator Guide Document Version 2011 06 5 7 2 SIP Settings...
Page 252: ...252 Administrator Guide Document Version 2011 06 7 4 Local Firmware Update...
Page 257: ...Index Document Version 2011 06 Administrator Guide 257...