BUSY_TONE_GAIN
Value Format
Integer
Description
Specifies the gain, in decibels, of the busy tone.
Value Range
-24–6
Default Value
0
BUSY_TONE_RPT
Value Format
Integer
Description
Specifies whether the busy tone is repeated.
Value Range
0–1
–
0: No Repeat
–
1: Repeat
Default Value
1
BUSY_TONE_TIMING
Value Format
Comma-separated Integer
Description
Specifies the pattern, in milliseconds, of busy tones using up to 10
whole numbers (off 1, on 1, off 2, on 2…) separated by commas.
Note
•
It is recommended that you set a value of 60 milliseconds or
more for the first value (off 1).
•
Avoid setting 1–50 for any of the values.
Value Range
0–16000 (0: Infinite time)
Default Value
60,500,440
REORDER_TONE_FRQ
Value Format
Comma-separated Integer
Description
Specifies the dual-tone frequencies, in hertz, of reorder tones using 2
whole numbers separated by a comma.
Value Range
0, 200–2000 (0: No tone)
Default Value
480,620
REORDER_TONE_GAIN
Value Format
Integer
Document Version 2013-03
Administrator Guide
201
4.4.2 Tone Settings
Summary of Contents for KX-UDS124
Page 146: ...146 Administrator Guide Document Version 2013 03 2 7 7 Restart ...
Page 164: ...164 Administrator Guide Document Version 2013 03 3 5 2 Example with Incorrect Descriptions ...
Page 250: ...250 Administrator Guide Document Version 2013 03 5 2 PS Registration using Provisioning ...
Page 280: ...280 Administrator Guide Document Version 2013 03 10 1 Troubleshooting ...
Page 281: ...Section 11 Appendix Document Version 2013 03 Administrator Guide 281 ...
Page 286: ...286 Administrator Guide Document Version 2013 03 11 1 Open Source Software ...
Page 287: ...Index Document Version 2013 03 Administrator Guide 287 ...
Page 289: ...Document Version 2013 03 Administrator Guide 289 Notes ...
Page 290: ...290 Administrator Guide Document Version 2013 03 Notes ...
Page 291: ...Document Version 2013 03 Administrator Guide 291 Notes ...