Download Timing
Explanation
At regular intervals of time
The configuration files are downloaded at specified intervals of time, set in
minutes. In the example below, the SIP-CS has been programmed to check
for and download configuration files from the provisioning server every 3
days (4320 minutes).
SIP-CS
Provisioning
Server
3 days later
Power On
6 days later
Check
Download
Check
Download
Check
Download
CFG_CYCLIC_INTVL="4320"
The configuration files are downloaded periodically under the following
conditions:
•
In the configuration file, add the line,
CFG_CYCLIC="Y"
.
–
Set an interval (minutes) by specifying "
CFG_CYCLIC_INTVL
".
•
In the Web user interface:
–
Click the
[Maintenance]
tab, click
[Provisioning Maintenance]
,
and then select
[Yes]
for
[Cyclic Auto Resync]
.
–
Enter an interval (minutes) in
[Resync Interval]
.
Note
•
The interval may be determined by your dealer. A maximum interval
of 28 days (40320 minutes) can be set on the SIP-CS.
Document Version 2013-03
Administrator Guide
155
3.2.4 Downloading Configuration Files
Summary of Contents for KX-UDS124
Page 146: ...146 Administrator Guide Document Version 2013 03 2 7 7 Restart ...
Page 164: ...164 Administrator Guide Document Version 2013 03 3 5 2 Example with Incorrect Descriptions ...
Page 250: ...250 Administrator Guide Document Version 2013 03 5 2 PS Registration using Provisioning ...
Page 280: ...280 Administrator Guide Document Version 2013 03 10 1 Troubleshooting ...
Page 281: ...Section 11 Appendix Document Version 2013 03 Administrator Guide 281 ...
Page 286: ...286 Administrator Guide Document Version 2013 03 11 1 Open Source Software ...
Page 287: ...Index Document Version 2013 03 Administrator Guide 287 ...
Page 289: ...Document Version 2013 03 Administrator Guide 289 Notes ...
Page 290: ...290 Administrator Guide Document Version 2013 03 Notes ...
Page 291: ...Document Version 2013 03 Administrator Guide 291 Notes ...