System Administrator
4-79
4.5.6
Hardware Settings
System Administration Top Menu
→
1
→
6
→
3
→
1
Program – Hardware – PBX Interface – Dialing Parameters Menu
PBX Type --------------------------------------------------------------- : Other
Integration Mode ------------------------------------------------------ : None
Operator Transfer Sequence ------------------------------------- : FX . . . . . . .
Extension Transfer Sequence ------------------------------------ : FX . . . . . . .
Alternate Extension Transfer Sequence ---------------------- : FX . . . . . . .
Reconnect Sequence on Busy ----------------------------------- : FWW . . . . . .
Reconnect Sequence on No-answer --------------------------- : FWW . . . . . .
Reconnect Sequence on Refuse Call ------------------------- : FWW . . . . . .
Light-On Sequence for Message Waiting Lamp ----------
: . . . . . . . . . .
Light-Off Sequence for Message Waiting Lamp ----------
: . . . . . . . . . .
Call Waiting Sequence --------------------------------------------- : . . . . . . . . . .
Release for Call Waiting ------------------------------------------- : . . . . . . . . . .
PBX Type
1. Other Manu-
factures
2. KX-T Series
1. T308
2. T616
3. T1232
4. T96
5. T336
6. TD816
7. TD1232
(Other)
Value Range
(default)
Specifies a type of PBX which is connected to the
VPS. In the case of a Panasonic KX-T series
telephone system, the model number should also
be specified.
[Note]
After selecting the PBX Type, the rest of the
Dialing Parameters are set automatically to each
PBX default values. Refer to the table on next
page.
Quick
Setup
p.4-8
Parameter
Description/Function
Reference