Note
•
The no. 4 and no. 5 pins (Master) of the CS must be connected to a pair of pins on the DHLC/DLC
card. Then use 4 consecutive pairs of pins on the DHLC/DLC card, starting with the pins corresponding
to the Master, as in the example above.
•
When connecting multiple KX-TDA0158CE CSs to a DHLC/DLC card, make sure that the no. 4 and
no. 5 pins (Master) of adjacent CSs are at least 3 pairs of pins away on the card.
•
CS connections must be made within the same DHLC/DLC card.
•
When a wrong connection is made, satisfactory performance of the CS cannot be guaranteed. Check
the connection of CS and the PBX using the Maintenance Console. For information about how to view
CS information using the Maintenance Console, refer to "2.6.14 Utility—CS Information" in the PC
Programming Manual.
KX-TDA0141CE
Signal Name
D1
D2
1
2
3
4
D1
D2
DHLC8 Card
DHLC/DLC card
(Amphenol)
Signal Name
Pin No.
CS (RJ11)
Cable Maximum Distance
ø 0.4 mm: 222 m
ø 0.5 mm: 347 m
ø 0.6 mm: 500 m
CAT 5: 347 m
Accessories and User-supplied Items for the CS
Accessories (included):
Screws
´
2, Washers
´
2
User-supplied (not included):
RJ11 connector
Note
For details about DHLC card or DLC card, refer to "2.7.2 DHLC8 Card (KX-TDA0170)", "2.7.3 DLC8 Card
(KX-TDA0171)", or "2.7.4 DLC16 Card (KX-TDA0172)".
Installation Manual
223
2.10.7 Connecting a Cell Station to the PBX
Summary of Contents for KX-TDA600 - Hybrid IP PBX Control Unit Max. 1008 Ports
Page 42: ...42 Installation Manual 1 4 3 System Capacity ...
Page 306: ...306 Installation Manual 2 16 1 Starting the PBX ...
Page 326: ...326 Installation Manual 4 1 5 Troubleshooting by Error Log ...
Page 327: ...Section 5 Appendix Installation Manual 327 ...
Page 330: ...330 Installation Manual 5 1 2 PLMPR Software File Version 5 0xxx ...
Page 331: ...Index Installation Manual 331 ...
Page 337: ...Installation Manual 337 Notes ...