2.9 Connection of Extensions
2.9.1 Maximum Cabling Distances of the Extension Wiring
(Twisted Cable)
SLT
Cable
Maximum
Distance
ø 0.4 mm:
500 m
ø 0.5 mm:
720 m
ø 0.6 mm:
830 m
CAT 5:
720 m
Cable
Maximum
Distance
ø 0.4 mm:
140 m
ø 0.5 mm:
229 m
ø 0.6 mm:
360 m
CAT 5:
229 m
Cable
Maximum
Distance
ø 0.4 mm:
698 m
ø 0.5 mm:
1128 m
ø 0.6 mm:
1798 m
CAT 5:
1128 m
Other PT (DPT/APT)
and DSS Console
KX-T7600 Series DPT
PT-interface CS
(Basic/High-density)
Cable
Maximum
Distance
ø 0.4 mm:
222 m
ø 0.5 mm:
347 m
ø 0.6 mm:
500 m
CAT 5:
347 m
Notice
•
If the cabling distance exceeds the maximum cabling distance above, satisfactory performance of each
terminal cannot be guaranteed.
•
The connected terminals will operate over the maximum cabling distance under optimum conditions.
However, the maximum cabling distance of SLTs connected to ports No. 9–24 of the ECSLC24 card
may be shorter than that of SLTs connected to the ESLC16 card.
PT-interface
CS
(Basic/
High-density)
DPT
APT
DSS
Console
SLT
DHLC8 Card
ü
ü
ü
ü
ü
EMSLC16, ESLC16,
ECSLC24, CSLC16,
SLC8 Cards
ü
192
Installation Manual
2.9.1 Maximum Cabling Distances of the Extension Wiring (Twisted Cable)
Summary of Contents for KX-TDA600 - Hybrid IP PBX Control Unit Max. 1008 Ports
Page 42: ...42 Installation Manual 1 4 3 System Capacity ...
Page 306: ...306 Installation Manual 2 16 1 Starting the PBX ...
Page 326: ...326 Installation Manual 4 1 5 Troubleshooting by Error Log ...
Page 327: ...Section 5 Appendix Installation Manual 327 ...
Page 330: ...330 Installation Manual 5 1 2 PLMPR Software File Version 5 0xxx ...
Page 331: ...Index Installation Manual 331 ...
Page 337: ...Installation Manual 337 Notes ...