2.2.11 Backup Battery Connection
The backup batteries and Back-up Battery Cable provide a backup power supply to allow full use of the PBX
in the event of a power failure. In case of power failure, the backup batteries automatically maintain the power
to the PBX without interruption.
User-supplied Items
•
Backup Batteries: VRLA (Valve Regulated Lead Acid) 12 V DC
´
3
•
Back-up Battery Cable: KX-A228 (for PSU-M) or KX-A229 (for PSU-L)
WARNING
There is a danger of explosion if backup batteries are incorrectly replaced. Replace only with the
same or equivalent type recommended by the battery manufacturer. Dispose of used batteries
according to the manufacturer's instructions.
CAUTION
•
Make sure that each Back-up Battery Cable is securely fastened to both the backup batteries and the
shelf.
•
Be sure to comply with applicable local regulations (e.g., laws, guidelines).
•
Make sure that the polarities of the backup batteries and wiring are correct.
•
Make sure that you do not short the backup batteries or cables.
•
Use the correct type of Back-up Battery Cable for the PSU.
Note
•
Turn on the battery switch on the PSU only after the installation of the shelves is finished and AC power
is available.
•
It is recommended to connect all installed shelves of the system to backup batteries. Note that backup
batteries can not provide a backup power supply to any shelves which are not directly connected to
the backup batteries.
•
The recommended maximum capacity per shelf is 28 Ah, to maintain effective battery charge.
•
Make sure that the type and capacity of the 3 backup batteries are identical.
•
The Back-up Battery Cable should not be exposed to direct sunlight. Keep the Back-up Battery Cable
and the backup batteries away from heating appliances and fire. Place the backup batteries in a
ventilated place.
•
For details about the backup batteries, refer to the manual for the batteries.
Backup Power Supply Duration
The length of time that backup batteries can power the shelves varies depending on the total load figure of the
shelves to which the backup batteries are connected. For how to calculate the load figure from the connected
items, refer to "Load Figure Calculation".
Examples
Battery Capacity
Total Load Figure of the
Connected Shelves
Backup Power Supply Duration
*1
28 Ah
128
5.5 h
512
3 h
*1
The duration may vary depending on the conditions.
Installation Manual
107
2.2.11 Backup Battery Connection
Summary of Contents for KX-TDA600 - Hybrid IP PBX Control Unit Max. 1008 Ports
Page 42: ...42 Installation Manual 1 4 3 System Capacity ...
Page 306: ...306 Installation Manual 2 16 1 Starting the PBX ...
Page 326: ...326 Installation Manual 4 1 5 Troubleshooting by Error Log ...
Page 327: ...Section 5 Appendix Installation Manual 327 ...
Page 330: ...330 Installation Manual 5 1 2 PLMPR Software File Version 5 0xxx ...
Page 331: ...Index Installation Manual 331 ...
Page 337: ...Installation Manual 337 Notes ...