2.10 Connection of DECT Portable Stations
2.10.1 Overview
Required Equipment and Maximum Number of Calls
CSs determine the area covered by the wireless system. The number of calls that can be made simultaneously
through each CS varies depending on the model, as follows:
CS
Connection Card
Maximum Calls
Compatible PSs
KX-TDA0158CE
DHLC/DLC
8
•
KX-TCA155
•
KX-TCA255
•
KX-TCA256
•
KX-TCA355
•
KX-TD7590
•
KX-TD7580
KX-TDA0141CE
DHLC/DLC
2
KX-TDA0142CE
CSIF
4
Notice
The CSs for DECT are for connection to specified Panasonic PBXs only.
Note
For more details about the PS, refer to the Operating Instructions of the PS.
Required Distances between Equipment
CAUTION
Maintain the distances listed below between equipment in order to prevent noise, interference or the
disconnection of a conversation. (The distance may vary depending on the environment.)
Equipment
Distance
CS and office equipment such as a computer, telex, fax
machine, etc., or microwaves
More than 2 m
CS and PS
More than 1 m
Each PS
More than 0.5 m
PBX and CS
More than 2 m
Notice
Too many CSs in a small area can cause problems due to conflicts over which signal channels each
CS can use. Ideally, CSs should be a minimum of 25 m to 40 m apart.
However, the required distance between CSs may vary depending on the environment of the
installation site and conditions in which the wireless system is used. Conduct the site survey to
determine the appropriate distance.
Installation Manual
203
2.10.1 Overview
Summary of Contents for KX-TDA600 - Hybrid IP PBX Control Unit Max. 1008 Ports
Page 42: ...42 Installation Manual 1 4 3 System Capacity ...
Page 306: ...306 Installation Manual 2 16 1 Starting the PBX ...
Page 326: ...326 Installation Manual 4 1 5 Troubleshooting by Error Log ...
Page 327: ...Section 5 Appendix Installation Manual 327 ...
Page 330: ...330 Installation Manual 5 1 2 PLMPR Software File Version 5 0xxx ...
Page 331: ...Index Installation Manual 331 ...
Page 337: ...Installation Manual 337 Notes ...