4.6
CO Line Programming
DID Wink Time Out Assignment
435
System Programming
4-107
Description
DID outgoing method can be set to wink mode in program [432]
“DID Outgoing Assignment.” This program sets the time the
system waits for the confirmation wink signal after CO line is
seized in accordance with the service of your central office. The
system disconnects the CO line when the time-out time expires.
Selection
• DID table number: 1 through 4,
(
=all DID tables)
• Time: 1 through 127 (
✕
64 milliseconds is the actual time)
Default
All DID tables – 16
Programming
1.
Enter 435.
Display: Wink Timeout
2.
Press NEXT.
Display: DID Table NO?–>
3.
Enter a DID table number.
To enter DID table number 1, you can also press NEXT.
Display example: 1:16
4.
Enter the time.
To change the current entry, press CLEAR and the new number.
5.
Press STORE.
6.
To program another DID table, press NEXT or PREV, or
SELECT and the desired DID table number.
7.
Repeat steps 4 through 6.
8.
Press END.
Conditions
• You cannot leave the entry empty.
• To assign all DID tables to one selection, press the
key at step 3. In
this case, the display shows the contents programmed for DID table
number 1.
Feature References
Section 3, Features,
Direct Inward Dialing (DID)