Programming References
Section 4, System Programming,
[806]–[807] EIA (RS-232C) Parameters — Port 1/Port 2
[815] System Working Report Printout
[816] System Working Report Clear
Feature References
Section 3, Features,
Station Message Detail Recording (SMDR)
T
ime-Out, Variable
Description
Provides timers to control various features or functions.
The following timers are programmable:
System Timer Items
Range
Automatic Redial Interval Time
n
~
10 s, n: 3 – 120
Automatic Redial Repeated Times
1 – 30 times
Call Forwarding – No Answer Time-Out
1 – 12 rings
CO Dial Starting Time
n
~
100 ms, n: 0 – 40
CO-to-CO Duration Time
1 – 64 min
Extension-to-CO Call Duration Time
1 – 64 min
Hold Recall Time
0 – 240 s
Intercept Routing Time-Out
3 – 48 rings
Message Waiting Ring Interval Time
0 – 64 min
Pickup Dialing Waiting Time
1 – 5 s
SMDR Duration Count Starting Time
0 – 60 s
Toll Restriction First Digit Time-Out
5 – 120 s
Toll Restriction Inter-digit Time-Out
5 – 30 s
Transfer Recall Time
3 – 48 rings
CO Line Group Timer Items
Disconnect Time
0.5 / 2.0 / 4.0 s
Register Recall Signal Time
Disable / 80 / 96 / 112 /
200 / 300 / 400 / 500 /
600 / 700 / 800 / 900 /
1000 / 1100 / 1200 ms
Pause Time
1.5 / 2.5 / 3.5 / 4.5 s
CO Line Timer Items
CPC Signal Detection Time
n
~
8 ms, n: 02 – 75
(Incoming)
DTMF Digit Time
80 / 160 ms