4.2
Manager Programming
DSS Console Port and Paired Telephone Assignment
(contd.)
007
4-28
System Programming
*: Available for KX-TD1232 only.
9.
Repeat steps 4 through 8.
10.
Press END.
Conditions
• There is a maximum of four DSS Consoles per system. System
Connection* permits eight DSS Consoles. Each DSS Console
must be assigned to a DSS Console jack and paired with a digital
proprietary telephone jack in the same system.
• For KX-TD816, DSS Consoles 1 through 4 must be assigned to a jack
number between 02 and 16.
• For KX-TD1232, DSS Consoles 1 through 4 must be assigned to a jack
number between 02 and 32 and DSS Consoles 5 through 8 must be
assigned to a jack number between 33 and 64, if available.
• DSS Consoles in the out-of-service system are unassignable. Jack
numbers in the out-of-service system are unacceptable.
• The jack number for the Console and that for the paired extension must
be entered together.
• Multiple DSS Consoles cannot be assigned to the same DSS Console
jack.
• Multiple DSS Consoles can be paired with the same digital proprietary
telephone jack.
• A DSS Console jack cannot be assigned the jack 01 and the jack
number of Manager set in program [006] “Operator / Manager
Extension Assignment.”
• If all incoming CO calls are set to ring at the operator extension
telephone in program [407]–[408] “DIL 1:1 Extension — Day /
Night,” assigning the DSS Consoles to the operator extension makes the
operator’s job much easier.
Feature References
Section 3, Features,
DSS Console (KX-T7240)