Troubleshooting
308
Installation Manual
(24) Digital trunk failure (RAI signal reception)
Error Code
1319 xyy: Digital trunk RAI signal reception
x = 1 to 3: Shelf number
yy = 01 to 14: Slot number
Possible cause of
the malfunction
1.
T1/PRI23 card (physical number xyy) received the RAI (Remote
Alarm Indication) signal sent from the Central Office.
Countermeasures
Ask the T1/PRI23 carrier to check the line conditions. Or check the
equipment in other switching system which your T1/PRI23 lines are
connected with.
Note
None