(12) Echo back error
Error Code
1300 xyy: Echo back error
x = 1 to 3: Shelf number
yy = 01 to 14: Slot number
Possible cause of
the malfunction
1.
Defective FIFO (First In First Out) trouble with a card
2.
Input/Output trouble (CPU card, Shelf)
Countermeasures
Note
*It is recommended to have a current copy of the program on disk to
facilitate accurate and rapid recovery.
Enter card test command from the
maintenance terminal.
Check the status of the
associated card.
Replace the faulty LPR card.
Enter card test command from the
maintenance terminal.
Replace the CPU card.
*
Enter card test command from the
maintenance terminal.
Replace the Shelf.
End
Enter INS (In-Service) command
from the maintenance terminal.
OK
OK
OK
OK
Faulty
Faulty
Faulty
Faulty