295
(11) SMDR Not Connect
Error Code
1203: SMDR Not Connect
Possible cause of
the malfunction
1.
RS-232C cable is not connected.
2.
RS-232C cable is defective.
3.
Printer is turned off. (including out of paper)
Countermeasures
Note
*It is recommended to have a current copy of the program on disk to
facilitate accurate and rapid recovery.
Do you use SMDR?
Check above item 1), 2), 3).
Replace the CPU card.
*
End
No
Faulty
Assign SMDR Connection to "No"
by System Programming.
Yes
No Problem