Troubleshooting
306
Installation Manual
(22) OPX power down
Error Code
1316 xyy: OPX power down
1317 xyy: OPX bell power down
x = 1 to 3: Shelf number
yy = 01 to 14: Slot number
Possible cause of
the malfunction
1.
Power-off of external OPX Unit or bell
2.
Defective OPX card
Countermeasures
Note
None
Check the port status of the related
OPX card.
Check the port status of the related
OPX card.
Check external OPX Power Unit
(Power, Power cable, Connector
etc.).
End
No "Faulty" port
Faulty port
No change in
condition
INS status
INS (In-Service) status
Replace the OPX card.
Power on the external OPX Power
Unit and then, enter INS (In-
Service) command from the main-
tenance terminal.