2.9 [3] Group
PC Programming Manual
217
Value Range
None, 10 × n (n=1–125) s
Maintenance Console Location
2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
Programming Manual References
None
Feature Manual References
1.9.4 ICD Group Features—Overflow
1.9.5 ICD Group Features—Queuing
Hurry-up Level
Specifies the number of calls to hold in the queue before prompting Manual Queue Redirection by
flashing the Hurry-up button.
Default
None
Value Range
None, 1–30
Maintenance Console Location
2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
Programming Manual References
2.10.4 [4-1-4] Wired Extension—Flexible Button
2.10.10 [4-2-3] Portable Station—Flexible Button
Feature Manual References
1.9.5 ICD Group Features—Queuing
Queuing Time Table
Floating Extension Number
Specifies the floating extension number of the incoming call distribution group.
Note that groups that will have a mailbox using a VM in DPT integration must have extension numbers
of 2–4 digits.
Default
Groups 001-064: 601–664
Groups 065-128: Not stored