2.9 [3] Group
196
PC Programming Manual
2.9
[3] Group
2.9.1
[3-1-1] Trunk Group—TRG Settings
CO lines can be organized into trunk groups. The settings of each trunk group determine the settings
of the CO lines within that group. A maximum of 64 trunk groups can be programmed.
For more information on trunk groups, see "1.7.1 GROUP FEATURES" in the Feature Manual.
Main
Group Name
Specifies the name of the trunk group for programming reference.
Default
Not stored.
Value Range
Max. 20 characters
Maintenance Console Location
2.9.1 [3-1-1] Trunk Group—TRG Settings
Programming Manual References
2.15.1 [9-1] CO Line Settings
Feature Manual References
None
COS
Specifies the COS of the trunk group.
If you wish to prevent such calls from being made, ensure that the COS specified here has a TRS
level of "7" assigned for all relevant time modes in
2.8.11 [2-7-1] Class of Service—COS Settings
.
Default
7
Value Range
1–64
Maintenance Console Location
2.9.1 [3-1-1] Trunk Group—TRG Settings
Programming Manual References
2.8.11 [2-7-1] Class of Service—COS Settings