5.1 Setting and operation
In this chapter, procedures for setting and operation of each communication system are explained
concretely.
Before reading this chapter, execute the necessary wireless units initial setting and slave
registration.
Reference
:
<Chapter 3 Initial setting/ Chapter 4 Resister slave>
Setting and operation are executed by main unit or by setting tool (Configurator KR).
Reference
:
<Help in setting tool (Configurator KR)>
5.2
Setting and operation of “1:1 topology”
5.2.1 Setting contents
Setting flow
According to the below flow it’s set. In this part it is assumed that setting of master and slave, slave
registration are completed. If not yet, refer to chapter 3 and 4 first.
Reference
:
<Chapter 3 Initial settings>
Initial setting of
master/slave
Reference
:
<Chapter 4 Register slave>
Slave registration
It is explained in this chapter.
Operation
during running
5.2.2 Operation during running
(1) Check again if the settings of switches in master and slave are correct or not.
・
Unit No. of master is set to “00”, Unit No. of slave is set to “01”.
・
Communication channels of master and slave are same.
・
MODE switch No.1 in master and slave are set to OFF.
No.2: Serial communication selection (RS232C/RS485) or data holding (available/not available)
No.3 to 8: Set baud rate, data length and parity according to the connected equipment.
(2) Set operating mode switch in master and slave to “RUN”.