Registration list view
Slave list that is registered to master is indicated. To indicate the list, execute “Transfer From Main
Unit”
Routing table view
Route from master to slave is indicated by tree-shaped structure. Name and Unit No. (number in
grouping symbol) are indicated in addition.
The left side of tree is upper level (the top level is master), the right side is lower level. And
mid-slave transfers the data to slave of right side by using repeater function. (In example, slave1
transfers data to slave2)
Terminal equipment list view
Terminal equipment that is connected to slave is indicated. By clicking slave in routing table view,
terminal equipment that is connected to the slave appears. (In example, slave3 is clicked)
1.4.2 System requirements
Software name
Configurator KR
OS
Windows
®
2000 / Windows
®
XP / Windows
®
Vista
Available hard disk space
More than 5MB
Recommended CPU
Pentium 300MHz or more
Recommended system RAM
More than 128MB (According to OS)
Recommended screen
resolution
800 x 600 or more
Recommended color quality
High Color (16bit) or more
1.4.3 Applicable cable
Type of computer and applicable cable (RS232C cable)
Type of
computer
Connector of
computer side
Connector of
wireless unit side
Specification
Recital
DOS/V
DSUB 9-pin
female
DSUB 9-pin female
straight type
Purchase commercial item.
Popular name :
For DOS/V RS232C cable
straight 9 pin type *
Note1) It is impossible to use setting tool via RS485 port of wireless unit.
Note2) It is recommended to use shielded cable.
Note3) To connect wireless unit to computer that has no serial port, USB/RS232C converter is
needed besides above cable.
* When using DSUB 9-pin female-female straight cable, connect computer and main unit directly.
If using male-female straight cable, use attached gender changer in main unit.
1-12