I/O type
1:N topology
setting by
setting tool
Data holding
Transmission
speed
Data
length
Parity
Function
Registration
overwriting
Not available
Not available
19200bit/s
8bit
Odd
Not
available
Not available
※
Stop bit is fixed with 1 bit.
Notes: 1. To make settings of each switch available, it is necessary to turn on power
supply again, or to change the operation mode switch.
2. For data holding function of I/O type, when output of communication error is
output, it is possible to select “Turn off output signal (OUT0-7 or OUT0-5)
coercively” or “Keep state of output that before communication error is output”
Communication style
Timing that communication error is output
(Time after wireless communication stopped)
1:1 topology
30 sec. with no communication
1:1 topology with repeaters
30 sec. with no communication
1:N topology (Polling)
More than 3 times of polling time with no communication
(30 sec. if 3 times of the time is less or equal to 30 sec.)
※
Polling: Master unit performs wireless communication with slave unit automatically in series.
(Polling time is time that master unit communicate to all slave units)
※
Event: It performs wireless communication only when upper level of master unit sends command.
ENTER switch
It functions as inputting the setting of each function.
2-10