Input signal time
For 1:1 topology and 1:1 topology with repeater of I/O type, input signal and output signal are not
always monitored, and only monitored when immediately before transmitting, and then
communicate the information. Therefore, if the input signal is shorter than the polling time, it may
not communicate to the output. To communicate reliably it is necessary to keep the input signal
longer than the polling time.
Response time
AKR2015
Wireless
communiactaion status
AKR2015
Master input signal
Master output signal
Slave output signal
Slave input signal
Wireless Com.
(Forward)
Master→Slave
Slave→Master
Master→Slave
Slave→Master
Master→Slave
Slave→Master
Change during wireless
communication can’t be transferred.
Polling time
Response time
Wireless Com.
(Backward)
Wireless Com.
(Forward)
Wireless Com.
(Backward)
Wireless Com.
(Forward)
Wireless Com.
(Backward)
*1
:
Polling time is the time cycle that transmit continuously from master to the slave.
*2
:
Response time is the time from the signal is input to the input terminal to the signal is output
from the output terminal of other.
Reference:
<9.2 Reference> I/O polling time
1.3.2 Functions Restrictions
Setting functions
Item
Main unit
Setting tool
Registering slave unit
(
Unit No. setting
)
Available
Available
Deleting the registration of the slave
Not available
Available
Change of communication channel
Available
Not available
Serial communication condition
Available
Not available
1:1 topology setting
Available
Available
1:1 topology with repeater setting
Not available
Available
Select of the
communicati
on style
1:N topology setting
Not available
Available
Setting of the master unit
(
Unit No., Name,
Communication protocol
)
Not available
Available
Routing setting (Slave unit, Terminal equipment)
Not available
Available
Name setting of the slave unit and the terminal
equipment
Not available
Available
Save the setting contents
Not available
Available
Initialize
Available
Not available
Setting
Flow control setting
Not available
Available
Test function and Utility
Item
Main unit
Setting tool
Confirmation of COM port connection
Not available
Available
Confirmation of status
Not available
Available
Communication test
Available
※
1
Available
Field intensity monitor
Available
※
2
Available
Read log
Not available
Available
Test
function and
utility
Remote reset
Not available
Available
※
1:Communication test is simple test by indicator LEDs.
※
2:Field intensity monitor is simple monitoring by indicator LEDs.
1-10