9-5
Functions specifications
Specifications
Item
RS485 type
I/O type
•
•
•
•
•
•
Operating mode change (SET, RUN, TEST)
Communication channel change (CH switch)
Unit No. change (UNIT No. switch)
Serial communication setup (MODE switch)
Slave registration
Initializing (Factory setting)
Setting function
-
•
Data holding (When communication
error)
Test function
•
•
Communication test: 3-stage LED display
(With setting tool, it can do various communication tests such as changing data
amount, including repeaters and so on. And it can measure an approximate
communication time.)
Field intensity monitor: 3-stage LED display
(With setting tool, it can display and record a field intensity of each channel by
numeric value.)
•
•
•
•
•
Distinguish master or slave (MASTER)
On communication, Power on (COM.)
On setting, Complete setting (SET)
Error, Alarm, Caution (ALARM)
Level indication (1,2,3: when using test function)
LED display
-
•
I/O operating display (16 or 12
1 point of communication
error)
Attachment ) Using frequency
・
Fixed channel: 76ch
・
Group channel: 89 group
It selects connectable channel from several foxed channels automatically.
When repeater function is used, use with the fixed channel.
The settable channel numbers is decreased in same communication area, and the communication
time becomes longer.
Usable communication channel
Communication style
Fixed channel
Group channel
1:1 topology
00 to 4Bch
All channel
1:1 topology with repeaters
00 to 4Bch
Disabled
1:N topology
00 to 4Bch
All channel only with no
repeaters