3.2 Initial setting of wireless unit
This is the explanation about the setting of the main unit of wireless unit.
Factory setting is as below figures.
3.2.1 Setting of operating mode
※
At factory setting, it’s set to “SET”
When setting by the main unit, it should be set to “SET”.
When transferring setting such as "transfer to main unit" and so on by using setting tool, be sure to
set to "SET".
Other items such as "transfer from main unit", "communication test" are available in RUN mode.
(Available with software version 1.20 or later.)
Usage restriction in RUN mode
Item
Usage availability
Transfer to Master Unit
Not available
File
Transfer from Main Unit
Available
Addition (Addition of slave registration)
Not available
Registration
list
Delete
(Delete slave registration)
Not available
Confirmation of COM port connection
Available
Confirmation of status
Available
Communication test
Available
Field intensity monitor
Available
Read log
Available
Initialize Log
Not available
Remote reset
Available
Utility
Flow control setting
Not available
*It is not available with software version 1.20 or less.
*Use it in SET mode for “Not available”.
Note: When setting, all wireless unit, master and slave, should be set to “SET”.
After completing setting, set to “RUN” to start operation.
When using test functions, set to “TEST”.