Communication Objects
ISE SMART CONNECT KNX Panasonic
1-000C-000
© 2019 ise Individuelle Software und Elektronik GmbH
S. 46 / 69
Table 19: Station selection
Table 20: Station status
12 | 112 | 212 | 312
Name
Station selection
Function
Switches program to the transferred value.
Communication object no. TV 1=12
TV 2=112
TV 3=212
TV 4=312
Possible values
1|...|999
Data width
2 bytes
Data point type/data type
7.001/pulse
Flags (CRWTUI)
C-W---
13 | 113 | 213 | 313
Name
Station status
Function
Indicates the number of the current program.
Communication object no. TV 1=13
TV 2=113
TV 3=213
TV 4=313
Details
This communication object is only supported by TV models from
manufacturing year 2019 onwards.
Station status is 0 if
• no programs are stored or
• another source, e.g. HDMI is currently selected
Possible values
Program channel as a number: 1|...|999
Data width
2 bytes
Data point type/data type
7.001
Flags (CRWTUI)
CR-T--