Communication Objects
ISE SMART CONNECT KNX Panasonic
1-000C-000
© 2019 ise Individuelle Software und Elektronik GmbH
S. 48 / 69
Table 23: Source status
Table 24: Supported sources
16 | 116 | 216 | 316
Name
Source status
Function
Indicates the number of the currently used source.
The value 255 is used for an unknown source.
The screen will be black if no device is connected to the selected
source.
Communication object no. TV 1=16
TV 2=116
TV 3=216
TV 4=316
Possible values
0|...|16 or 255
Number of the current source or unknown source
Data width
1 byte
Data point type/data type
5.010/meter pulse
Flags (CRWTUI)
CR-T--
No.
Source
No.
Source
0
Switch off
9
Video2
1
TV mode
10
Component1
2
Analogue TV
11
HDMI1
3
DVB-T
12
HDMI2
4
DVB-S
13
HDMI3
5
Freesat
14
HDMI4
6
DVB-C
15
DisplayPort
7
SAT_IP
16
SD-USB
8
Video1
255
Unknown