Item
Specifications
Comparison match 0 flag or comparison match 1 flag can be allocated to external
output.
ON hold time can be set only when the band comparison function is used.
ON hold time: 0 to 1,000 ms
● Only the comparison match 0 flag or comparison match 1 flag can be set as the external output
function.
● By default, the external output 0 and external output 1 signals are set to "Not output". When
necessary, change the setting in the Counter_Configuration parameter window.
● There is no need to arrange comparison data items in ascending or descending order.
■
Target value match comparison and band comparison
The main differences are as below.
Main differences in characteristics
Item
Target value match comparison
Band comparison
Setting of
comparison value
data
Comparison value data is specified as a
target value.
Comparison value data is specified as a
band (lower and upper limits).
Setting for
comparison value
data match
One of the following four options is specified
as the comparison match flag behavior to be
performed when the target value is reached.
"Addition set pattern": Sets the flag when the
current value and comparison value match
at the time of incrementation
"Addition reset pattern": Resets the flag
when the current value and comparison
value match at the time of incrementation
"Subtraction set pattern": Sets the flag when
the current value and comparison value
match at the time of decrementation
"Subtraction reset pattern": Resets the flag
when the current value and comparison
value match at the time of decrementation
ON or OFF is specified as the behavior of
the comparison match flag when the current
value falls within the specified band.
Behavior when
comparison value
data matches
The behavior that is performed when the
current value matches the same comparison
value data may differ between incremental
count and decremental count, depending on
the settings.
The behavior that is performed when the
current value matches the same comparison
value data is the same for incremental count
and decremental count.
External output
signal ON hold
time
Cannot be set
ON hold time: 0 to 1,000 ms
■
Parameter settings for target value match comparison
Parameter setting procedure
1. Click
Counter parameter
>
Counter (Ch0 or Ch1)
>
Comparison function
, change the
"Select comparison function" parameter to "Target value match comparison", and execute
"Set number of comparison data".
12.6 High-speed Counter Function
12-42
WUME-GM1RTXOP-01
Summary of Contents for GM1 Series
Page 1: ...Motion Controller GM1 Controller RTEX User s Manual Operation WUME GM1RTXOP 01 2021 2 ...
Page 2: ... MEMO 2 WUME GM1RTXOP 01 ...
Page 6: ... MEMO vi WUME GM1RTXOP 01 ...
Page 16: ... MEMO xvi WUME GM1RTXOP 01 ...
Page 20: ...1 3 Software License Agreement 1 3 Software License Agreement 1 4 WUME GM1RTXOP 01 ...
Page 21: ...1 3 Software License Agreement WUME GM1RTXOP 01 1 5 ...
Page 22: ...1 3 Software License Agreement 1 6 WUME GM1RTXOP 01 ...
Page 28: ... MEMO 2 6 WUME GM1RTXOP 01 ...
Page 66: ... MEMO 3 38 WUME GM1RTXOP 01 ...
Page 76: ...4 6 Project Configuration 4 6 Project Configuration 4 10 WUME GM1RTXOP 01 ...
Page 102: ... MEMO 4 36 WUME GM1RTXOP 01 ...
Page 231: ...The POU object of the program will be added to the task 7 9 Tasks WUME GM1RTXOP 01 7 65 ...
Page 240: ...8 2 Connecting the GM1 Controller and PC 8 4 WUME GM1RTXOP 01 ...
Page 270: ... MEMO 8 34 WUME GM1RTXOP 01 ...
Page 287: ...9 4 Monitoring Function WUME GM1RTXOP 01 9 17 ...
Page 299: ...9 7 Device Trace Function WUME GM1RTXOP 01 9 29 ...
Page 300: ...9 7 Device Trace Function 9 30 WUME GM1RTXOP 01 ...
Page 314: ... MEMO 9 44 WUME GM1RTXOP 01 ...
Page 362: ... MEMO 10 48 WUME GM1RTXOP 01 ...
Page 372: ...When Modulo is selected 11 1 RTEX Axis Setting 11 10 WUME GM1RTXOP 01 ...
Page 394: ...11 3 Single axis Operation 11 32 WUME GM1RTXOP 01 ...
Page 397: ...ST program 11 3 Single axis Operation WUME GM1RTXOP 01 11 35 ...
Page 399: ...ST program 11 3 Single axis Operation WUME GM1RTXOP 01 11 37 ...
Page 407: ...11 4 Synchronous Operation WUME GM1RTXOP 01 11 45 ...
Page 418: ... Preinterpolation tab 11 5 Multi axis Operation 11 56 WUME GM1RTXOP 01 ...
Page 419: ... Table editor tab 11 5 Multi axis Operation WUME GM1RTXOP 01 11 57 ...
Page 421: ... Common tab Build tab 11 5 Multi axis Operation WUME GM1RTXOP 01 11 59 ...
Page 422: ... Access Control tab 11 5 Multi axis Operation 11 60 WUME GM1RTXOP 01 ...
Page 462: ... MEMO 11 100 WUME GM1RTXOP 01 ...
Page 479: ...ST program 12 5 PWM Output WUME GM1RTXOP 01 12 17 ...
Page 526: ... MEMO 12 64 WUME GM1RTXOP 01 ...
Page 587: ...Implementation section ST programming language 14 1 SD Card Access WUME GM1RTXOP 01 14 5 ...
Page 588: ...Implementation section LD programming language 14 1 SD Card Access 14 6 WUME GM1RTXOP 01 ...
Page 591: ...Implementation section LD programming language 14 1 SD Card Access WUME GM1RTXOP 01 14 9 ...
Page 598: ... MEMO 14 16 WUME GM1RTXOP 01 ...
Page 646: ... MEMO App 4 WUME GM1RTXOP 01 ...
Page 648: ... MEMO WUME GM1RTXOP 01 ...
Page 649: ... MEMO WUME GM1RTXOP 01 ...
Page 650: ...Panasonic Corporation 2021 February 2021 WUME GM1RTXOP 01 ...