Configurator PMX settings
■
Sample program
The execution condition is differential execution. For details of instructions, refer to
■
Operation at over limit input
Conditions
Direction
Limit status
Operation
At startup
Forward
Over limit input (+): ON
Executable
Over limit input (-): ON
Executable
Reverse
Over limit input (+): ON
Executable
Over limit input (-): ON
Executable
During operation
Forward
Over limit input (+): ON
Automatic reverse
operation
Over limit input (-): ON edge
Limit stops, Error occurs.
Reverse
Over limit input (+): ON edge
Limit stops, Error occurs.
Over limit input (-): ON
Automatic reverse
operation
(Note 1)
Only when an edge signal is detected, the limit stop is performed.
(Note 2)
In the case of home position method, it cannot be executed.
(Note 3)
In the case of data set method, it cannot be executed.