Settings when using table setting mode (Transistor output type)
Parameter
name
No. and setting item
Settings
Control Unit
input settings
(HSC / PLS)
400
High-speed counter
setting
(X0 to X3)
X0
To use the J-point control, select J-point positioning start
input of CH0.
X1
To use the J-point control, select J-point positioning start
input of CH1.
X2
Select CH4 Home input or Normal input.
X3
Select CH5 Home input or Normal input.
Control Unit
input settings
2 (HSC / PLS)
401
High-speed counter
pulse output setting
(X4 to X7)
X4
Select CH0 Home input or Normal input.
X5
Select CH1 Home input or Normal input.
X6
Select CH2 Home input or Normal input.
X7
Select CH3 Home input or Normal input.
Control Unit
output
settings
(PLS / PWM)
407 Positioning control mode
setting
Select the table setting mode or FP-X compatible
instruction mode.
402
Pulse / PWM output
setting
(Y0 to YB)
CH0
Select the output allocated to each channel.
Normal output, PWM output, Pulse output [Table setting
mode],
Pulse output [FP-X compatible instruction mode]
CH1
CH2
CH3
CH4
CH5
(Note 1)
Displayed items vary according to models.
(Note 2)
Select "Normal input" and "Normal output" for the input and output that is not used for the pulse
output function or high-speed counter function.
(Note 3)
"J-point positioning start input" for each channel can be selected only when "Table setting mode"
is set in the system register no. 407.
Settings when using table setting mode (Relay output type)
Parameter
name
No. and setting item
Settings
Pulse I/O
cassette
setting
(HSC / PLS)
407 Positioning control mode
setting
Select the table setting mode or FP-X compatible
instruction mode.
400 High-speed
counter setting
(X100 to X102)
X100
To use the J-point control, select J-point positioning start
input of CH0.
400 Pulse output
setting
(Y100 and Y101)
CH0
Select the output allocated to each channel.
Normal output, PWM output, Pulse output [Table setting
mode],
Pulse output [FP-X compatible instruction mode]
400 High-speed
counter setting
(X200 to X202)
X200
To use the J-point control, select J-point positioning start
input of CH1.
400
Pulse output setting
CH1
Select the output allocated to each channel.
Normal output, PWM output, Pulse output [Table setting
mode],
4.3 System Register Settings
4-18
WUME-FPXHPOSG-01
Summary of Contents for FP-XH Series
Page 2: ... MEMO 2 WUME FPXHPOSG 01 ...
Page 18: ... MEMO 1 10 WUME FPXHPOSG 01 ...
Page 30: ... MEMO 3 8 WUME FPXHPOSG 01 ...
Page 51: ...4 4 Reading Elapsed Values WUME FPXHPOSG 01 4 21 ...
Page 52: ... MEMO 4 22 WUME FPXHPOSG 01 ...
Page 88: ... MEMO 5 36 WUME FPXHPOSG 01 ...
Page 94: ... MEMO 6 6 WUME FPXHPOSG 01 ...
Page 140: ... MEMO 9 8 WUME FPXHPOSG 01 ...
Page 193: ... MEMO WUME FPXHPOSG 01 ...
Page 194: ...Panasonic Industrial Devices SUNX Co Ltd 2020 October 2020 WUME FPXHPOSG 01 ...