10.5.2 Interrupt Activation When F165 (CAM0) is Executed
For the cam control instruction F165 (CAM0), the start condition varies according to the
magnitude of the ON set value and OFF set value. Also, the interrupt program is activated with
each target value of up to 32 points.
■
Activation of interrupt program
ON set value < OFF set value
ON set value > OFF set value
ON set value = OFF set value
When added
When subtracted
Description
When the elapsed value is larger
than or equal to the ON set value
and smaller than the OFF set
value, the interrupt program is
activated.
When the elapsed value is smaller
than the ON set value and larger
than or equal to the OFF set value,
the interrupt program is activated.
When the elapsed value
reaches the ON set value (=
OFF set value), the interrupt
program is activated.
10.5 Interrupt Program Activation
10-32
WUME-FPXHPOSG-01