1.
Select
Debug
>
Check Parameter and Data Values
from the menu bar.
A message box appears to show the check result. If there is an error in the settings for the
positioning data tables, an error message will appear and the cursor will move to the
corresponding error position.
4.2.7 Writing Parameters to Unit (1)
● Information on parameters that have been set is transferred to the unit along with information
on programs, comments and system registers.
● The following procedure is explained on the condition that the Configurator PMX has already
started.
1.
Select
File
>
Save changes and exit
from the menu bar of the Configurator PMX.
2.
When "Do you save the setting?" appears, press [Yes (Y)].
3.
Select
Online
>
Download To PLC (Entire project)
from the FPWIN GR7 menu bar.
Positioning data will also be downloaded to the control unit along with information on
programs, comments and system registers.
4.2.8 Writing Parameters to Unit (2)
● Information on parameters that have been set can also be downloaded to the unit in the
Configurator PMX.
● The following procedure is explained on the condition that the Configurator PMX has already
started.
1.
Select
File
>
Download positioning data
from the menu bar of the Configurator PMX.
A message box for confirming the saving appears.
4.2 Settings in Configurator PMX
WUME-FPXHPOSG-01
4-15
Summary of Contents for FP-XH Series
Page 2: ... MEMO 2 WUME FPXHPOSG 01 ...
Page 18: ... MEMO 1 10 WUME FPXHPOSG 01 ...
Page 30: ... MEMO 3 8 WUME FPXHPOSG 01 ...
Page 51: ...4 4 Reading Elapsed Values WUME FPXHPOSG 01 4 21 ...
Page 52: ... MEMO 4 22 WUME FPXHPOSG 01 ...
Page 88: ... MEMO 5 36 WUME FPXHPOSG 01 ...
Page 94: ... MEMO 6 6 WUME FPXHPOSG 01 ...
Page 140: ... MEMO 9 8 WUME FPXHPOSG 01 ...
Page 193: ... MEMO WUME FPXHPOSG 01 ...
Page 194: ...Panasonic Industrial Devices SUNX Co Ltd 2020 October 2020 WUME FPXHPOSG 01 ...