12.4 Table of Error codes
Difference in ERROR display
There are differences in the way errors are displayed depending on the model.
Model
Display
Display method
FP1,FP-M,FP2,FP3,FP10SH
LED
ERROR.
Continually lit
FP
Σ
,FP0, FP-X
LED
ERROR/ALARM
Flashes/contunually lit
FP-e
Screen display
ERR.
Continually lit
Error Confirmation When ERROR Turns ON
When the “ERROR” on the control unit (CPU unit) turns on or flashes, a self-diagnostic error or syntax
check error has occurred. Confirm the contents of the error and take the appopriate steps.
-Error Confirmation Method
Procedure:1.Use the programming tool software to call up the error code.
By executing the “STATUS DISPLAY”, the error code and content of error are
displayed.
2.Check the error contents in the table of error codes using the error code
ascertained above.
-Syntax check error
This is an error detected by the total check function when there is a syntax error or incorrect setting
written in the program. When the mode selector is switched to the RUN mode, the total check function
automatically activates and eliminates the possibility of incorrect operation from syntax errors in the
program.
When a syntax check error is detected
-ERROR turns on or flashes.
-Operation will not begin even after swirching to the RUN mode.
-Remote operation cannot be used to change to RUN mode.
Clearing a syntax check error
By changing to the PROG.mode, the error will clear and the ERROR will turn off.
Steps to take for syntax error
Change to the PROG. mode, and then execute the total check function while online mode with the
programming tool connected. This will call up the content of error and the address where the error
occurred.
Correct the program while referring to the content of error.
Summary of Contents for FP E Series
Page 1: ......
Page 16: ......
Page 17: ...Chapter 1 Functions and Restrictions of the Unit ...
Page 28: ...1 12 ...
Page 29: ...Chapter 2 Specifications and Functions of the Unit ...
Page 37: ...2 9 Circuit diagram C32 Y0 Y1 Y3 Y4 C28 Y0 Y1 Y3 Y4 Y2 Y5 to YF Y2 Y5 to YB ...
Page 48: ...2 20 ...
Page 49: ...Chapter 3 Expansion ...
Page 56: ...3 8 Terminal layout diagram Note The numbers in the connector are for the first expansion ...
Page 61: ...Chapter 4 I O Allocation ...
Page 66: ...4 6 ...
Page 67: ...Chapter 5 Installation and Wiring ...
Page 90: ...5 24 ...
Page 91: ...Chapter 6 High speed counter Pulse Output and PWM Output functions ...
Page 116: ...6 26 ...
Page 121: ...6 31 ...
Page 125: ...6 35 Pulse output diagram ...
Page 131: ...6 41 ...
Page 139: ...6 49 ...
Page 141: ...6 51 ...
Page 144: ...6 54 Program Continued on the next page ...
Page 145: ...6 55 ...
Page 147: ...6 57 Program ...
Page 151: ...Chapter 7 Communication Cassette ...
Page 210: ...7 60 The values of DT50 and DT51 are written in DT0 and 1 of PLC ...
Page 238: ...7 88 ...
Page 239: ...Chapter 8 Self Diagnostic and Troubleshooting ...
Page 247: ......
Page 248: ......
Page 249: ...Chapter 9 Precautions During Programming ...
Page 260: ...9 12 Example 2 Using the CT instruction between JP and LBL instructions ...
Page 268: ...9 20 ...
Page 269: ...Chapter10 Specifications ...
Page 286: ......
Page 287: ...Chapter 11 Dimensions ...
Page 290: ...11 4 11 1 3 Expansion Unit FPG XY64D2T FPG XY64D2P FPG EM1 ...
Page 293: ...Chapter 12 Appendix ...
Page 297: ...12 5 ...
Page 437: ...12 145 12 7 ASCII Codes ...
Page 439: ......
Page 440: ......