12-17
WR906
Relay No.
Name
Description
R9060
Unit
No.1
Turns on when Unit No. 1 is communicating properly in
PC(PLC) link 0 mode. Turns off when operation is stopped,
when an error occurs, or when not in the PC(PLC) link 0 mode.
R9061
Unit
No.2
Turns on when Unit No. 2 is communicating properly in
PC(PLC) link 0 mode. Turns off when operation is stopped,
when an error occurs, or when not in the PC(PLC) link 0 mode.
R9062
Unit
No.3
Turns on when Unit No. 3 is communicating properly in
PC(PLC) link 0 mode. Turns off when operation is stopped,
when an error occurs, or when not in the PC(PLC) link 0 mode.
R9063
Unit
No.4
Turns on when Unit No. 4 is communicating properly in
PC(PLC) link 0 mode. Turns off when operation is stopped,
when an error occurs, or when not in the PC(PLC) link 0 mode.
R9064
Unit
No.5
Turns on when Unit No. 5 is communicating properly in
PC(PLC) link 0 mode. Turns off when operation is stopped,
when an error occurs, or when not in the PC(PLC) link 0 mode.
R9065
Unit
No.6
Turns on when Unit No. 6 is communicating properly in
PC(PLC) link 0 mode. Turns off when operation is stopped,
when an error occurs, or when not in the PC(PLC) link 0 mode.
R9066
Unit
No.7
Turns on when Unit No. 7 is communicating properly in
PC(PLC) link 0 mode. Turns off when operation is stopped,
when an error occurs, or when not in the PC(PLC) link 0 mode.
R9067
Unit
No.8
Turns on when Unit No. 8 is communicating properly in
PC(PLC) link 0 mode. Turns off when operation is stopped,
when an error occurs, or when not in the PC(PLC) link 0 mode.
R9068
Unit
No.9
Turns on when Unit No. 9 is communicating properly in
PC(PLC) link 0 mode. Turns off when operation is stopped,
when an error occurs, or when not in the PC(PLC) link 0 mode.
R9069
Unit
No.10
Turns on when Unit No. 10 is communicating properly in
PC(PLC) link 0 mode. Turns off when operation is stopped,
when an error occurs, or when not in the PC(PLC) link 0 mode.
R906A
Unit
No.11
Turns on when Unit No. 11 is communicating properly in
PC(PLC) link 0 mode. Turns off when operation is stopped,
when an error occurs, or when not in the PC(PLC) link 0 mode.
R906B
Unit
No.12
Turns on when Unit No. 12 is communicating properly in
PC(PLC) link 0 mode. Turns off when operation is stopped,
when an error occurs, or when not in the PC(PLC) link 0 mode.
R906C
Unit
No.13
Turns on when Unit No. 13 is communicating properly in
PC(PLC) link 0 mode. Turns off when operation is stopped,
when an error occurs, or when not in the PC(PLC) link 0 mode.
R906D
Unit
No.14
Turns on when Unit No. 14 is communicating properly in
PC(PLC) link 0 mode. Turns off when operation is stopped,
when an error occurs, or when not in the PC(PLC) link 0 mode.
R906E
Unit
No.15
Turns on when Unit No. 15 is communicating properly in
PC(PLC) link 0 mode. Turns off when operation is stopped,
when an error occurs, or when not in the PC(PLC) link 0 mode.
R906F
MEWNET-W0
PC(PLC) link
0
transmission
assurance
relay
Unit
No.16
Turns on when Unit No. 16 is communicating properly in
PC(PLC) link 0 mode. Turns off when operation is stopped,
when an error occurs, or when not in the PC(PLC) link 0 mode.
Summary of Contents for FP E Series
Page 1: ......
Page 16: ......
Page 17: ...Chapter 1 Functions and Restrictions of the Unit ...
Page 28: ...1 12 ...
Page 29: ...Chapter 2 Specifications and Functions of the Unit ...
Page 37: ...2 9 Circuit diagram C32 Y0 Y1 Y3 Y4 C28 Y0 Y1 Y3 Y4 Y2 Y5 to YF Y2 Y5 to YB ...
Page 48: ...2 20 ...
Page 49: ...Chapter 3 Expansion ...
Page 56: ...3 8 Terminal layout diagram Note The numbers in the connector are for the first expansion ...
Page 61: ...Chapter 4 I O Allocation ...
Page 66: ...4 6 ...
Page 67: ...Chapter 5 Installation and Wiring ...
Page 90: ...5 24 ...
Page 91: ...Chapter 6 High speed counter Pulse Output and PWM Output functions ...
Page 116: ...6 26 ...
Page 121: ...6 31 ...
Page 125: ...6 35 Pulse output diagram ...
Page 131: ...6 41 ...
Page 139: ...6 49 ...
Page 141: ...6 51 ...
Page 144: ...6 54 Program Continued on the next page ...
Page 145: ...6 55 ...
Page 147: ...6 57 Program ...
Page 151: ...Chapter 7 Communication Cassette ...
Page 210: ...7 60 The values of DT50 and DT51 are written in DT0 and 1 of PLC ...
Page 238: ...7 88 ...
Page 239: ...Chapter 8 Self Diagnostic and Troubleshooting ...
Page 247: ......
Page 248: ......
Page 249: ...Chapter 9 Precautions During Programming ...
Page 260: ...9 12 Example 2 Using the CT instruction between JP and LBL instructions ...
Page 268: ...9 20 ...
Page 269: ...Chapter10 Specifications ...
Page 286: ......
Page 287: ...Chapter 11 Dimensions ...
Page 290: ...11 4 11 1 3 Expansion Unit FPG XY64D2T FPG XY64D2P FPG EM1 ...
Page 293: ...Chapter 12 Appendix ...
Page 297: ...12 5 ...
Page 437: ...12 145 12 7 ASCII Codes ...
Page 439: ......
Page 440: ......