10-9
High-speed counter, pulse output and PWM output specifications
Item
Descriptions
No. of input
points
When using single-phase: Max. 4
channels
When using 2-phase: Max. 2
channels
Used ch.
Note2)
ch0 to ch4
ch0, ch2
Max. counting
speed
When using single-phase:
for 1 channel: Max. 50kHz (x1ch)
for 2 channels: Max. 30kHz (x2ch)
for 3 or 4 channels: Max. 20kHz (x3
to 4ch)
When using 2-phase:
for 1 channel: Max. 20kHz (x1ch)
for 2 channels: Max. 15kHz (x2ch)
Input mode
When using single-phase:
Addition input,
Subtraction input
When using 2-phase:
Two-phase input, One input,
Direction distinction input
High
speed
coun-
ter
Input contact
used
Note1)
When using single-phase:
X0: count input (ch0)
X1: count input (ch1)
X2: reset input (ch0, ch1)
X3: count input (ch2)
X4: count input (ch3)
X5: reset input (ch2, ch3)
When using 2-phase:
X0, X1: count input (ch0)
X2: reset input (ch0)
X3, X4: count input (ch2)
X5: reset input (ch2)
No. of output
points
Max. 2 channels
Used ch
Note2)
ch0, ch2
Output mode
CW and CCW mode, Pulse and Sign mode
Max. output
frequency
When using 1 channel: Max.
100kHZ (x1ch)
When using 2 channels: Max.
60kHz (x2ch)
When using linear interpolation
function: Max. 100kHz
When using circular interpolation
function: Max. 20kHz
Pulse
output
Input/output
contact used
Note1)
<ch0>
X2: Home input
Y0: CW output (Pulse output)
Y1: CCW output (Sign output)
Y2: Deviation counter reset output
<ch2>
X5: Home input
Y3: CW output (Pulse output)
Y4: CCW output (Sign output)
Y5: Deviation counter reset output
No. of output
points
Max. 2 channels
Used ch
Note2)
ch0, ch2
Output
frequency
1.5 to 12.5kHz (at resolution of 1000), 15.6 to 41.7kHZ
(at resolution of 100)
Output duty
0.0 to 99.9% (at resolution of 1000), 1 to 99% (at reslution of 100)
PWM
output
Output
contact used
Note1)
<ch0>Y0, <ch2>Y3
Note1)The contacts noted above cannot be allocated for more than one function. Also, contacts that are
not assigned to the various functions can be used as general inputs/outputs. Inputs functions can
be used as general inputs/outputs. Inputs X0 to X5 are pulse catch inputs, and can also be used
for interrupt input.
Note2)The pulse output, PWM output and high-speed counter of the same channel cannot be used at
the same time.
Summary of Contents for FP E Series
Page 1: ......
Page 16: ......
Page 17: ...Chapter 1 Functions and Restrictions of the Unit ...
Page 28: ...1 12 ...
Page 29: ...Chapter 2 Specifications and Functions of the Unit ...
Page 37: ...2 9 Circuit diagram C32 Y0 Y1 Y3 Y4 C28 Y0 Y1 Y3 Y4 Y2 Y5 to YF Y2 Y5 to YB ...
Page 48: ...2 20 ...
Page 49: ...Chapter 3 Expansion ...
Page 56: ...3 8 Terminal layout diagram Note The numbers in the connector are for the first expansion ...
Page 61: ...Chapter 4 I O Allocation ...
Page 66: ...4 6 ...
Page 67: ...Chapter 5 Installation and Wiring ...
Page 90: ...5 24 ...
Page 91: ...Chapter 6 High speed counter Pulse Output and PWM Output functions ...
Page 116: ...6 26 ...
Page 121: ...6 31 ...
Page 125: ...6 35 Pulse output diagram ...
Page 131: ...6 41 ...
Page 139: ...6 49 ...
Page 141: ...6 51 ...
Page 144: ...6 54 Program Continued on the next page ...
Page 145: ...6 55 ...
Page 147: ...6 57 Program ...
Page 151: ...Chapter 7 Communication Cassette ...
Page 210: ...7 60 The values of DT50 and DT51 are written in DT0 and 1 of PLC ...
Page 238: ...7 88 ...
Page 239: ...Chapter 8 Self Diagnostic and Troubleshooting ...
Page 247: ......
Page 248: ......
Page 249: ...Chapter 9 Precautions During Programming ...
Page 260: ...9 12 Example 2 Using the CT instruction between JP and LBL instructions ...
Page 268: ...9 20 ...
Page 269: ...Chapter10 Specifications ...
Page 286: ......
Page 287: ...Chapter 11 Dimensions ...
Page 290: ...11 4 11 1 3 Expansion Unit FPG XY64D2T FPG XY64D2P FPG EM1 ...
Page 293: ...Chapter 12 Appendix ...
Page 297: ...12 5 ...
Page 437: ...12 145 12 7 ASCII Codes ...
Page 439: ......
Page 440: ......