147
UF-9000
JAN 2004
Ver. 1.0
DP-180/190
5.1.4.
F5 Mode: Function Parameters (For Copier)
Set the machine to Service Mode and press "5" key on the Keypad.
↓
Press the "START" key.
↓
Enter the desired code number or press “V”, ”/\” arrow keys.
↓
If you wish to select another code number, scroll the menu with the arrow keys.
↓
Press the "SET" key.
↓
Enter the desired function code number and press “SET” key.
↓
When the “CLEAR” key is pressed, the selected code input will not be accepted.
↓
Press “STOP” key, then press “FUNCTION” and “CLEAR” keys simultaneously to exit the service mode.
↓
Reboot the machine after setting the parameter(s) to activate the setting(s).
F5 Mode
No.
Item
Function
Default Setting
00
Not Used
01
Frequency Desired
0 : Auto
1 : 50 Hz
2 : 60Hz
2 (for USA / Canada)
1 (for Europe)
02-03 Not Used
04
LSU Off Timer
1 : 5 sec.
2 : 10 sec.
3 : 15 sec.
4 : 20 sec.
6 : 30 sec.
8 : 40 sec.
10 : 50 sec.
12 : 60 sec.
1
05-12 Not Used
13
Paper Out Red Indicator
0 : On
1 : Off
0
14
Paper Size (Tray 1)
(UF-9000)
4 : A4-R
12 : LEGAL
14 : LETTER-R
14 (for USA / Canada)
4 (for Europe / Others)
Paper Size (Tray 1)
(DP-180/190)
4 : A4-R
5 : B5
7 : A5
9 : 8 x 13
10 : 8.5 x 13
12 : LEGAL
14 : LETTER-R
Summary of Contents for DP-180/190
Page 48: ...48 UF 9000 JAN 2004 Ver 1 0 DP 180 190 20 Remove the LCD Module 127 ...
Page 72: ...72 UF 9000 JAN 2004 Ver 1 0 DP 180 190 3 3 Preventive Maintenance Points ...
Page 123: ...123 UF 9000 JAN 2004 Ver 1 0 DP 180 190 Sensor and Switch Location ...
Page 264: ...264 UF 9000 JAN 2004 Ver 1 0 DP 180 190 memo ...
Page 266: ...266 JAN 2004 Ver 1 0 UF 9000 DP 180 190 memo ...
Page 295: ...memo ...
Page 296: ...DZZSM00249 ...