128
UF-9000
JAN 2004
Ver. 1.0
DP-180/190
415
XMT
(Polling)
B
Remote side attempted to receive
message from your machine in
polling communication.
Inform the remote side that your
machine does not have the polling
transmission feature.
416
RCV
D
Receiver did not detect post
command, such as EOP, MPS,
EOM, etc.
Transmitter is defective.
Line quality is poor. (RTC signal is
distorted due to line noise)
SC PCB or FXB PCB are defective.
417
RCV
C
Receiver returned RTN in
response to post message.
Line quality is poor. (There are
excessive errors in received data)
SC PCB or FXB PCB are defective.
418
RCV
C
Receiver transmitted PIN in
response to PRI-Q from
transmitter. (Transmitting operator
requests voice contact)
Line quality is poor. (There are
excessive errors in received data)
SC PCB or FXB PCB are defective.
420
RCV
B
T1 timer (35 sec.) elapsed without
detecting 300 bps signal.
Incorrect incoming call type (voice).
(Non-facsimile communication)
Transmitter is defective.
SC PCB or FXB PCB are defective.
421
RCV
B
Busy Tone is detected after
sending NSF Signal.
Remote station disconnected the line.
Wrong number is dialed.
422
XMT
B
Content of NSF (or DIS) or NSC
(or DTC) was invalid.
There is an incompatibility.
427
G3
RCV
B
DCN received to NSF/CSI/DIS
transmitted.
The interface is incompatible.
434 XMT or RCV
B
CD (response from Modem) did
not turn OFF within 180 sec. after
receiver detected FLAG signal.
Remote unit is defective.
SC PCB or FXB PCB are defective.
436
G3 RX
C
DCN received after transmitting
FTT.
Transmitter is defective or incompatible.
Line quality is poor.
456
RCV
B
Received relay transfer request or
confidential document to distribute
to an end receiving station or all
confidential mailboxes are used.
457 RELAY XMT
CONF. XMT/
POLL
B
Remote unit does not have
Relayed XMT or Confidential
Comm. capability.
459
RCV
C
Failed training in Phase C.
Line quality is poor. (Training signal is
distorted due to line noise)
SC PCB or FXB PCB are defective.
490
RCV
C
Sum of error lines exceeded the
limit (Function Parameter No. 70)
of 64 lines.
Line quality is poor.
SC PCB or FXB PCB are defective.
494
RCV
C
Interval between two EOLs was
more than 10 sec. when receiver
received message data.
Transmitter is defective.
Line quality is poor. (EOL is damaged
due to line noise)
SC PCB or FXB PCB are defective.
495
XMT
RCV
C
During reception, CD turned OFF
or continued ON for long time.
During communication, lost loop -
current.
Line is disconnected.
Transmitter is defective.
SC PCB or FXB PCB are defective.
Fax Information Codes
Code
Mode
Phase
Description of Problem
Cause
Summary of Contents for DP-180/190
Page 48: ...48 UF 9000 JAN 2004 Ver 1 0 DP 180 190 20 Remove the LCD Module 127 ...
Page 72: ...72 UF 9000 JAN 2004 Ver 1 0 DP 180 190 3 3 Preventive Maintenance Points ...
Page 123: ...123 UF 9000 JAN 2004 Ver 1 0 DP 180 190 Sensor and Switch Location ...
Page 264: ...264 UF 9000 JAN 2004 Ver 1 0 DP 180 190 memo ...
Page 266: ...266 JAN 2004 Ver 1 0 UF 9000 DP 180 190 memo ...
Page 295: ...memo ...
Page 296: ...DZZSM00249 ...