z
SNMP
Make SNMP functionality related settings. You can check the status of
the unit by using the SNMP manager to connect.
The setting is confirmed with the [Set] button.
SNMP [On, Off]
Sets whether to use the SNMP function.
Factory settings:
Off
User name
Sets the user name used for user authentication.
You need to specify the same user name that you set here in the
SNMPv3 manager.
Maximum number
of characters
0 to 32 characters
Characters that
cannot be entered Double-byte
Authentication
Sets the algorithm used for user authentication.
MD5
MD5 is used as the algorithm for user authentication.
SHA1
SHA1 is used as the algorithm for user authentication.
Factory settings:
MD5
Encryption method
Sets the encryption method used for communications.
DES
DES is used as the encrypted communication method for
SNMPv3.
AES
AES is used as the encrypted communication method for
SNMPv3.
Factory settings:
DES
Password
Sets the password used for user authentication.
You need to specify the same password that you specified here in the
SNMPv3 manager.
Maximum number
of characters
When [Authentication] is set to [MD5]:
8 to 16 characters
When [Authentication] is set to [SHA1]:
8 to 20 characters
Characters that
cannot be entered Double-byte
System name
Enter the device name used to manage this unit using SNMP
functionality.
Maximum number
of characters
0 to 32 characters
Characters that
cannot be entered Double-byte
Location
Sets the location where this unit has been installed.
Maximum number
of characters
0 to 32 characters
Characters that
cannot be entered Double-byte
Contact
Enter the email address or phone number of the administrator.
Maximum number
of characters
0 to 255 characters
Characters that
cannot be entered Double-byte
z
TSL5.0
Make settings related to TSL protocol version 5.0. Set the information
required to control the tallies of this unit from a device that supports the
TSL5.0 protocol with the TSL5.0 function.
The setting is confirmed with the [Set] button.
Index number [1 to 65534]
By matching the INDEX set on the TSL5.0 control device and the
Index number of this unit, you can control the tallies of this unit
individually.
Factory settings:
1
TSL5.0 Port [1 to 65535]
Sets the port number that will receive controls via the TSL 5.0
protocol.
Factory settings:
62000
z
Referrer check
By enabling Referrer check, you can confirm that the device requesting
access to the camera is legitimate.
Access is refused if it is determined that the device attempting access is
unauthorized.
Depending on the environment in which the unit is being used, it may
not be possible to access the unit when Referrer check is enabled.
If this occurs, you can access the unit by disabling Referrer check, but
you will no longer be able to determine if the device attempting access is
unauthorized.
Enable
The Referrer check function is used.
Disable
The Referrer check function is not used.
Factory settings:
Enable
138
139
Web screen configurations (continued)