Maintenance and Inspections : Warning System
The following error codes are displayed in the display window if an error occurs in the camera:
Confirm the type of warning and refer to the details in the [Warning Description Tables] (page 145) for countermeasures.
Error Codes
Code No.
Description
Type of warnings
E-11
Video initialisation error
E-27
Recording control error
E-30
P2 card removal error
E-34
LCD microcontroller error
E-38
P2 streaming microcontroller error
E-39
Abnormal initialization of the AVC-Intra codec board
E-3F
Image sequence error (in case of 24P, 30P and 25P)
6. Image Sequence Error (24P, 30P, 25P)
E-40
Microprocessor error in the camera control circuit.
E-63
Something is wrong with the system control microprocessor.
E-6F
Reference signal error.
00:00:00:11
Recording error on a P2 card
1394 Error Codes
Code No.
Description
Recording
Indication in display
window
1394 E-82
Signals being input to the DVCPRO connector
are not 1
a
speed transfer signals in
DVCPRO50 (50 Mbps) format.
Stops
The time code section of the
display window indicates the
appropriate error code that
blinks every two seconds.
1394 E-83
Incorrect signals are being input to the
DVCPRO connector.
Stops
1394 E-84
Signals being input to the DVCPRO connector
are not in DVCPRO format.
Stops
1394 E-85
Signals being input to the DVCPRO connector
are not 1x speed transfer signals in DVCPRO
HD format.
Stops
1394 E-87
Incorrect audio signals are being input to the
DVCPRO connector.
Continues with no sound.
1394 E-90
No signal is supplied to the DVCPRO
connector.
While the recording mode
continues, no data is recorded on
cards unless the abnormal
condition is corrected. If an error
has occurred before recording,
then, recording does not start.
1394 E-92
The DVCPRO connector is not properly
connected. The viewfinder indicates the
message "1394 INITIAL ERROR."
No recording in 1394 input mode
can be performed.
Card Warning Code
Code No.
Description
Recording
Indication in display
window
E-70
The directory organization on the inserted P2
card does not comply with the standards.
([DIR NG CARD (Slot No.)] is indicated on the
viewfinder.)
Although different kinds of recording
operations will function, data may not be
recorded properly. Use the unit to format the
card immediately.
A warning code blinks once
every 2 seconds on the time
code display section of the
display window.
E-71
A P2 card was inserted where the number of
rewrites exceeds the limit of the standards.
([RUN DOWN CARD (Slot No.)] is indicated
on the viewfinder.)
Although different kinds of recording
operations will function, data may not be
recorded properly. It is recommended to
replace it.
AJ-HPX3000G(VQT1D27)E.book 152 ページ 2007年9月3日 月曜日 午後2時34分