186
Menu : Menu Description Tables
Note
Please refer to [Setting UMID Information] (page 66) for the
UMID information setting.
The ____ in the Adjustable Range column indicates the
preset mode.
Items/
Data Saved
Adjustable
Range
Remarks
TCG SET
HOLD
ON
OFF
ON/OFF switching for the feature that
always starts recording (when the power
is turned ON again) the TCG value that
was set before the power is turned OFF.
– C U F –
FIRST REC
TC
PRESET
REGEN
For the first recording after the power is
turned on, a P2 card is inserted and
then switching from this P2 card to
another recording-target P2 card is
performed, select whether or not to
regenerate the time code as the value
on the new P2 card.
PRESET:
Use the camera-recorder’s internal
time code.
REGEN:
For clips recorded on the recording-
target P2 card, regenerate the time
code as the time code of the clip that
has the most recent date and time.
Notes
z
Set the date and time accurately. For
guidance on setting, see [
Internal Clock’s Date and Time
59).
z
During operation in either 24P or
24PA mode, regeneration of the value
of the card recorded in drop-frame is
not permitted.
– C U F –
P.OFF LCD
DISPLAY
ON
OFF
Select whether or not to display the time
code setting and counter indication on
the LCD monitor when the power is
turned OFF.
ON:
Display setting and indication while
the power is turned OFF.
OFF:
Power-down LCD monitor while
camera power is turned OFF.
Setting and indication disabled.
– C U F –
TC OUT
TCG
TCG/TCR
Select the time code to be output to the
time code output connector.
TCG:
Always output time code generator
value.
TCG/TCR:
Display time code generator value
in recording mode, and time code
reader value in playback mode.
– C U F –
TC DISP SEL 30F
24F
Select the display format for the time
code frame digits. (For 1080-59.94i or
480-59.94i only
)
For details, refer to
[Recording time code and user bits]
(page 56).
30F:
Display time code frame digits in 30
frames.
24F:
Convert time code frame digits into
24 frames for display.
– C U F –
TC VIDEO
SYNCRO
0
1
2
3
For setting to correct the time code
according to the delay of video signals.
0:
Do not correct.
1:
To delay the time code to be input
according to the timing of the video
images.
2:
To forward the time code to be output
according to the timing of the video
images.
3:
To delay the time code to be input and
forward the time code to be output,
respectively, according to the timing of
the video images.
For details, refer to [Externally Locking
the Time Code] (page 61).
– C U F –
Items/
Data Saved
Adjustable
Range
Remarks
REC REVIEW
REGEN
ON
OFF
For selecting whether the time code is
regenerated to the value on the P2 card
or not, when subsequent recording
starts after setting the RET SW item on
the SW MODE screen to R.REVIEW
and pressing the RET button on the lens
or the USER button on the unit on which
the RET SW function is assigned.
ON:
The time code is regenerated to
the value on the tape.
OFF:
The time code is not regenerated.
– C U F –
UMID SET/INFO
Items/
Data Saved
Adjustable
Range
Remarks
COUNTRY
NO-INFO
Input the user’s country. NO-INFO is
displayed until the input completes.
– C U F –
ORGANIZATION NO-INFO
Input the user’s organisation or
company name. NO-INFO is displayed
until the input completes.
– C U F –
USER
NO-INFO
Input the user name. NO-INFO is
displayed until the input completes.
– C U F –
DEVICE
NODE
Indicate the product ID number.
– – – – –
AJ-HPX3000G(VQT1D27)E.book 186 ページ 2007年9月3日 月曜日 午後2時34分