150
Maintenance and Inspections : Warning System
5. P2 Card Fully Recorded
Display window
indication
All 7 bar indicators for remaining MEDIA
capacity start blinking.
WARNING lamp
This lamp will illuminate continuously until an
operation is made after recording.
Tally lamp
This lamp will flash 4 times every second
until an operation is made after recording.
Viewfinder
The END indicator blinks.
Warning tone
This tone will sound continuously until an
operation is made after recording.
Warning
description
The P2 cards are recorded to maximum
capacity.
Recording/
playback
operation
The recording stops.
Countermeasures
Delete the clips in the P2 card or insert a
new P2 card.
7. Recording Error
Display window
indication
“00:00:00:11” appears in the time code
display field. Even after recording is stopped,
this display continues to blink until the next
operation is performed.
WARNING lamp
Blinks 4 times per second while recording
continues.
Tally lamp
Blinks 4 times per second while recording
continues.
Viewfinder
The REC WARNING indicator lights up.
Warning tone
Beeps 4 times per second while recording
continues.
Warning
description
This indicates a failure either in the P2 card
recording or the recording circuit. This is
displayed when attempting to record clips
where the total quantity exceeds the upper
limit (1000 pieces) for a single P2 card.
Recording/
playback
operation
The recording may stop or continue.
Countermeasures
Restart recording. Or, turn the power OFF
and turn it ON again, before starting
recording.
6. Image Sequence Error (24P, 30P, 25P)
Display window
indication
“E-40” appears in the time code display field.
WARNING lamp
Blinks 4 times per second.
Tally lamp
Blinks 4 times per second while recording
continues.
Viewfinder
The REC WARNING indicator lights up.
Warning tone
Beeps 4 times per second while recording
continues.
Warning
description
There are abnormal conditions in the image
sequence of the 24P, 30P, or 25P mode.
Recording/
playback
operation
Images can be recorded and played back,
but some frames may be dropped or the
sequences of TC and UB may shift.
Countermeasures
Confirm the recording/playback operation
after turning OFF the power supply once and
then turning it on again. If the error is not
corrected after executing this procedure,
contact the dealer.
8. Low Wireless Signal Reception
Display window
indication
No display.
WARNING lamp
Blinks 4 times per second. (During pause
and recording)
Tally lamp
Blinks 4 times per second while recording
continues.
Viewfinder
The WIRELESS RF indicator lights up while
recording continues.
Warning tone
Beeps 4 times per second while recording
continues.
Warning
description
This error indicates poor wireless audio
reception conditions.
Recording/
playback
operation
Continues to operate without receiving the
wireless microphone signal.
Countermeasures
Check the microphone power supply and the
reception status of the wireless receiver.
AJ-HPX3000G(VQT1D27)E.book 150 ページ 2007年9月3日 月曜日 午後2時34分