Code
(ASCII)
Content
Description
21
NACK error
A data error occurred during the communication.
(e.g.) Parity error, framing error
27
Frame over error A certain command or response is 118 byte or more.
40
BCC
error
A transmission error occurred in the command data.
41
Format error
A command message does not match the transmission format.
(e.g.) Parity error, framing error
"
㧏
" or "transmission destination" is not contained in the message.
42
NOT support error
A command that is not supported was transmitted.
A command was transmitted to a transmission destination
that is not supported.
53
Busy error
The previous command is being processed when a message
was received.
60
Parameter error
The function designated parameter has an incorrect code.
61
Data error
There is an error in the designation of the contact No.,
data No. or data code format.
(e.g.) Set data is out of the designated range.
˴˴˴˴
62
Registeration error Number of registeration exceeded when monitoring data.
63
Mode error
When the command was transmitted, the operation mode
of the inverter was one that could not process the command.
1) Parameter data setting during the inverter is operating.
2) Parameter data setting during the inverter has an error.
䃂㩷
Error Codes in Communication
Commands are ignored when an error occurred in communication.
Following error codes are returned to the computer from the inverter in such cases.